FORMAT
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Content Description Per NFPA's requirements, when purchasing NFPA 2021 Standards and/or 2020 NFPA 70 (NEC), you must subscribe to at least one more NFPA Standard to complete your purchase. In order to fulfill this requirement, we automatically add 2019 NFPA 900 to your cart. This title may be removed during checkout if you choose to add a different NFPA standard to your cart, and pricing will be recalculated accordingly.
Apply NFPA 484, Standard for Combustible Metals, to help ensure that you meet the most advanced fire and explosion safety requirements related to combustible metals and metal dusts. NFPA 484, Standard for Combustible Metals, was developed in response to fires where fire suppression water was used inappropriately, often with disastrous results. The standard includes widely accepted safety requirements for any metal that meets its definition of a combustible metal, including alkali metals, aluminum, hafnium, magnesium, niobium, tantalum, titanium, and zirconium. NFPA 484, Standard for Combustible Metals, addresses the production, processing, finishing, handling, storage, use, and recycling of all metals and alloys that are in a form capable of combustion or explosion. Make sure you understand and follow the requirements for proper dust collection, housekeeping, and identification of potential ignition sources. It\\'s important to understand that fire and explosion hazards might be present due to operations involving the production, processing, finishing, handling, recycling, storage, and use of all metals and alloys that are in a form that is capable of combustion or explosion. Operations where metal or metal alloys are subjected to processing or finishing operations that can produce combustible powder or dust are also covered by this standard. Changes throughout the 2022 edition of NFPA 484, Standard for Combustible Metals, can help you apply the standard correctly in different work environments. This edition of the standard has been reorganized so that the first nine chapters correlate with the topics covered in NFPA 652, Standard on the Fundamentals of Combustible Dust, as well as to organize the remaining chapters to ensure the first nine chapters do not conflict with other sections of the standard. Chapter 13, Additive Manufacturing, was also revised to address the following: The growing utilization of metal powders in additive manufacturing Dust hazard analysis Location of emergency shutdown controls Harvesting printed objects Powder storage Operator training Further updates for the 2022 edition of NFPA 484, Standard for Combustible Metals, include the following: A new requirement for the Kst value to be doubled for certain metals — unless their explosibility characteristics are determined in a 1 m3 or larger test vessel — has been added, in addition to annex material to help explain this requirement. The requirements for fire detection for dry-type air-material separators have been revised to allow for the use of methods other than surface-mounted devices and to require that all filter locations (if present) be monitored. Chapter 15, Legacy Metals, has been reorganized to consolidate the requirements that apply to all legacy metals.
The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com NFPA subscriptions are annual and access is concurrency based (number of people that can access the subscription at any given time).
Some features of MADCAD.com NFPA Subscriptions are:
- Floating concurrency model: Set your concurrency level and share your NFPA Subscriptions among your offices enterprise-wide.
- Immediate Access: As soon as the transaction is completed, your NFPA Subscription will be ready for access.
For any further information on MADCAD.com NFPA Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About NFPAThe mission of the international nonprofit NFPA, established in 1896, is to reduce the worldwide burden of fire and other hazards on the quality of life by providing and advocating consensus codes and standards, research, training, and education.
The world's leading advocate of fire prevention and an authoritative source on public safety, NFPA develops, publishes, and disseminates more than 300 consensus codes and standards intended to minimize the possibility and effects of fire and other risks.
NFPA membership totals more than 70,000 individuals around the world
|
GROUPS
|