Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
FORMAT
EDITION
to
PUBLISHER
(1)
(337)
(589)
(54)
(234)
(996)
(657)
(2161)
(117)
(94394)
(54)
(568)
(124)
(33)
(21)
(20)
(94534)
(3)
(17)
(1)
(374)
(315)
(6631)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • NFPA
    NFPA 37: Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines
    This title can only be subscribed to with another NFPA title (See details)
    Edition: 2015
    $187.74
    / user per year

Content Description

Per NFPA's requirements, when purchasing NFPA 2021 Standards and/or 2020 NFPA 70 (NEC), you must subscribe to at least one more NFPA Standard to complete your purchase. In order to fulfill this requirement, we automatically add 2019 NFPA 900 to your cart. This title may be removed during checkout if you choose to add a different NFPA standard to your cart, and pricing will be recalculated accordingly.
Update to the 2015 edition of NFPA 37: Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines for the latest on safe engine operation. Minimize fire hazards by staying up-to-code. The 2015 edition of NFPA 37 governs the installation and use of stationary engines and gas turbines fueled by liquid or gaseous fuels as prime movers for emergency generators, fire pumps, and stand-by and peak power systems. Requirements address system installation, fuel supplies, lubricating systems, engine exhaust systems, control and instrumentation, instructions, and fire protection features. Designers, installers, and AHJs will work more efficiently and confidently with the latest provisions, including key changes: General installation requirements for engines and turbines are revised to require compliance with wind and seismic design criteria. Subsection 5.2.1 is amended to specify the type of regulator required and other changes that enhance the safety of the fuel supply system. Revision in Subsection 5.2.2 allows the use of a proof-of-closure switch or a valve proving system as alternatives to a vent valve between the two automatic safety shutoff valves -- providing greater flexibility for system designers. New Subsection 9.3.3 reinstates the vital requirement for a purge cycle in the start cycle for combustion gas turbines. Paragraphs 11.4.4.1.1 and 11.4.4.2 are revised to clarify the performance criteria for total flooding gaseous agent suppression systems and local application gaseous agent suppression systems with respect to cool-down of the engine or turbine. Annexes to both paragraphs above are revised to incorporate additional clarification and a new Subsection 11.4.8 has been added to address retrofit of existing fire suppression systems. These amendments help the user ensure that suppression systems will perform as intended. Loss prevention professionals; designers and installers of stationary engines for fire pumps, standby power supplies, and emergency generators; insurers; and AHJs need the 2015 edition of NFPA 37 to help improve safe engine operation and minimize fire hazards.

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
NFPA
[+] $1,015.43 Buy
VAR
NFPA
[+] $1,100.84 Buy
VAR
NFPA
[+] $2,286.65 Buy
VAR
NFPA
[+] $1,262.17 Buy
VAR
NFPA
[+] $2,656.50 Buy
VAR
NFPA
[+] $2,390.85 Buy
VAR
NFPA
[+] $1,005.94 Buy
VAR
NFPA
[+] $970.43 Buy

Subscription Information

MADCAD.com NFPA subscriptions are annual and access is concurrency based (number of people that can access the subscription at any given time).

 

Some features of MADCAD.com NFPA Subscriptions are:

 

- Floating concurrency model: Set your concurrency level and share your NFPA Subscriptions among your offices enterprise-wide.

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access NFPA Standards from any browser on your computer, tablet or smart phone.

- Customized Subscriptions: Select different number of concurrencies based on your needs. Set higher number of seats for more used NFPA Subscriptions and lower seats on standards with less need.

 

- Immediate Access: As soon as the transaction is completed, your NFPA Subscription will be ready for access.

 

For any further information on MADCAD.com NFPA Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About NFPA

The mission of the international nonprofit NFPA, established in 1896, is to reduce the worldwide burden of fire and other hazards on the quality of life by providing and advocating consensus codes and standards, research, training, and education.

 

The world's leading advocate of fire prevention and an authoritative source on public safety, NFPA develops, publishes, and disseminates more than 300 consensus codes and standards intended to minimize the possibility and effects of fire and other risks.

 

NFPA membership totals more than 70,000 individuals around the world

 

GROUPS