Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
FORMAT
EDITION
to
PUBLISHER
(1)
(337)
(589)
(55)
(234)
(996)
(690)
(2161)
(117)
(94624)
(54)
(575)
(124)
(33)
(21)
(20)
(94991)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    PD CLC/TS 50612:2013 Portable electrical apparatus for the measurement of combustion flue gas parameters. Guide to their use in the process of commissioning, servicing and maintaining gas fired central heating boilers
    Edition: 2014
    $435.35
    / user per year

Description of PD CLC/TS 50612:2013 2014

This Technical Specification provides guidance on the selection, use and maintenance of portable electrical apparatus conforming to EN 50379 1 [4] and EN 50379 2 [5] or EN 50379 3 [6] designed to measure combustion flue gas parameters of Type B and Type C gas-fired central heating boilers (hereafter referred to as boilers) using 1st, 2nd or 3rd family gases in domestic premises as a diagnostic instrument to assist an operative: a) in confirming satisfactory combustion at the time of commissioning, in accordance with appliance instructions or national or local regulations or standards; b) in confirming satisfactory combustion at the time of servicing in accordance with national or local regulations or standards or following servicing in accordance with appliance instructions; c) in confirming satisfactory combustion following maintenance, in accordance with appliance instructions or national or local regulations or standards. NOTE 1 Type B and Type C classification of gas-fired appliances are described in CEN/TR 1749 [1]. NOTE 2 Existing national or local regulations or standards conflicting with the guidance in this Technical Specification have precedence over this guidance. NOTE 3 It is not the intention of this Technical Specification to suggest that portable electrical combustion flue gas analysers are to be used as a substitute for normal service and maintenance carried out in accordance with the appliance instructions. Clause 9 describes how analysers can be used in conjunction with the appliance instructions. NOTE 4 EN 50379 1 [4] specifies general requirements for the construction, testing and performance of portable spot reading apparatus designed to check the combustion performance of heating appliances in domestic premises, using commercially available fuels. NOTE 5 EN 50379 2 [5] is for apparatus intended to be used for statutory measurements. In several European countries, legal requirements exist for the performance of heating appliances (see informative Annex A of EN 50379 1:2012 [4]). Legal consequences resulting from performance measurements makes for strict requirements for the apparatus used (see normative Annexes B and C of EN 50379 1:2012 [4]). NOTE 6 EN 50379 3 [6] is for apparatus intended to be used for non-statutory applications, which allows for reduced performance requirements for the portable electrical apparatus. NOTE 7 This Technical Specification deals with the determination of levels of combustion gases such as carbon monoxide (CO) and carbon dioxide (CO2) in combustion products from boilers. Combustion products from boilers will contain nitrogen oxides (NOX), predominantly nitrogen monoxide (nitric oxide, NO) and nitrogen dioxide (NO2). This Technical Specification does not deal with the measurement of combustion products such as NOX and aldehydes.

About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

GROUPS