Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
FORMAT
EDITION
to
PUBLISHER
(1)
(337)
(589)
(54)
(234)
(996)
(657)
(2161)
(117)
(94394)
(54)
(568)
(124)
(33)
(21)
(20)
(94534)
(3)
(17)
(1)
(374)
(315)
(6631)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS ISO 3567:2011 Vacuum gauges. Calibration by direct comparison with a reference gauge
    Edition: 2012
    $435.35
    / user per year

Description of BS ISO 3567:2011 2012

This International Standard specifies the physical, technical and metrological conditions to be fulfilled when calibrations of vacuum gauges are performed by direct comparison with a reference gauge. From the conditions described, the design of an apparatus that can perform vacuum gauge calibrations in an adequate manner can be deduced.

The vacuum gauges to be calibrated can be of any kind. Many types of gauges consist of several parts. Typically, these are: gauge head, cable, operational device and signal read out. This entire set is considered as the unit that has to be calibrated. Whereas, if only the gauge head (i.e. the part of the vacuum gauge directly exposed to the vacuum) is calibrated, all set-ups and conditions would have to be recorded such that the user of the calibrated gauge head would be able to perform the measurements in the same manner as during the calibration.

The reference gauge is either a calibrated gauge, traceable to a vacuum primary or national standard (normal case), with a calibration certificate according to ISO/IEC 17025, or an absolute measuring instrument (rare case), traceable to the SI units and to which a measurement uncertainty can be attributed.

This International Standard does not give guidance on how to treat special types of vacuum gauges, be they reference standards or units under calibration; it is intended that such guidance be given in other International Standards.

The pressure range for calibrations treated in this International Standard depends on the realized design of the calibration apparatus and on the type of reference gauge. The range varies in its limits from 10-6 Pa to 110 kPa.