FORMAT
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN IEC 61010-2-201:2018 2018This clause of Part 1 is applicable, except as follows. 1.1.1 Equipment included in scopeReplacement:
Components of the above named equipment and in the scope of this standard are:
Control equipment and their associated peripherals are intended to be used in an industrial environment and may be provided as open or enclosed equipment. NOTE 1 Control equipment intended also for use in other environments or for other purposes (example: for use in building installations to control light or other electrical installations, or for use on cars, trains or ships) can have additional conformity requirements defined by the safety standard(s) for these applications. These requirements can involve as example: insulation, spacings and power restrictions. NOTE 2 Computing devices and similar equipment within the scope of IEC 60950 (planned to be replaced by IEC 62368 ) and conforming to its requirements are considered to be suitable for use with control equipment within the scope of this standard. However, some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in IEC 61010‑1:2010, 5.4.4 second paragraph. Control equipment covered in this standard is intended for use in overvoltage category II, III and IV ( IEC 60664‑1 ) in low-voltage installations, where the rated equipment supply voltage does not exceed AC. 1 000 V r.m.s. (50/60 Hz), or DC 1 000 V. The requirements of ISO/IEC Guide 51 and IEC Guide 104 , as they relate to this part of IEC 61010 , are incorporated herein. 1.1.2 Equipment excluded from scopeReplacement: This standard does not deal with aspects of the overall automated system, e.g. a complete assembly line. Control equipment (e.g. DCS and PLC), their application program and their associated peripherals are considered as components (components in this context are items which perform no useful function by themselves) of an overall automated system. Since control equipment (e.g. DCS and PLC) are component devices, safety considerations for the overall automated system including installation and application are beyond the scope of this standard. Refer to IEC 60364 series of standards or applicable national/local regulations for electrical installation and guidelines. 1.2.1 Aspects included in scopeReplacement: The purpose of the requirements of this standard is to ensure that all hazards to the operator, service personnel and the surrounding area are reduced to a tolerable level. NOTE 1 By using the terms " operator" and " service personnel" this standard considers the perception of hazards depending on training and skills. Annex AA gives a general approach in this regard. Requirements for protection against particular types of hazard are given in Clauses 6 to 17, as follows:
NOTE 2 Attention is drawn to the existence of additional requirements regarding the health and safety of labour forces. 1.2.2 Aspects excluded from scopeReplacement: This standard does not cover:
The following editions for this book are also available...
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|