Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
FORMAT
EDITION
to
PUBLISHER
(1)
(326)
(572)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(535)
(117)
(33)
(20)
(19)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS EN 61168:1994, BS 5724-3.129:1994, IEC 61168:1993 Medical electrical equipment. Particular requirements for performance. Methods of declaring functional performance characteristics of radiotherapy simulators
    Edition: 1994
    $411.69
    / user per year

Description of BS EN 61168:1994 1994

Scope

This International Standard applies to radiotherapy simulators which use diagnostic X-ray equipment to geometrically simulate a radiotherapy radiation beam so that the treatment volume to be irradiated during radiotherapy can be localized and the position and size of the therapeutic radiation field can be confirmed.

This standard applies to radiotherapy simulators using high voltage generators operating at a voltage not exceeding 400 kV complying with IEC 601-2-7.

This standard applies to radiotherapy simulators intended exclusively for radiotherapy simulation as a prelude to intended radiotherapy and not for any other purposes such as general diagnostic purposes.

The requirements in this standard are based on the assumption that the radiotherapy simulator consists of:

  1. a system for producing a beam of X-radiation not exceeding 400 kV which simulates the geometry of the radiotherapy radiation beam:

  2. a system for producing images of the transmitted X-ray beam, either by radiography or by radioscopy;

  3. an assembly which controls the size of the radiation beam and which delineates the intended treatment area;

  4. a mechanical structure that physically simulates the geometry and motions of a radiotherapy equipment, and which supports an imaging system;

  5. a patient support system.

This standard applies to equipment intended for use under the supervision of a qualified person.

Except where otherwise stated this standard assumes that the radiotherapy simulator has an isocentric gantry with no pitch or roll movement of the radiation head.

This standard specifies type tests to be performed by the manufacturer at the design and construction stages of a radiotherapy simulator but does not specify site tests to be performed after installation at the user's site. The accompanying technical report IEC 1170, however, does suggest that many of the test procedures are appropriate for site tests.

During the course of any test procedure only those adjustments of the radiotherapy simulator are permissible that can be carried out using controls normally accessible to the operator and which are regarded as forming part of the normal operation of the radiotherapy simulator.

1.2 Object

The object of this standard is to:

  1. identify geometric parameters which are critical for the accurate simulation of a radiotherapy treatment;

  2. recommend methods of measuring these parameters.

It is recognized that inaccuracies in the test methods must be allowed for when assessing performance. However, it is not felt advisable to combine the errors into an overall performance tolerance but keep them separate in the expectation that more accurate test methods will be evolved.

It is not intended that this standard should in any way inhibit the future development of new designs of equipment which may have operating modes and parameters different from those described herein.

1.3 Environmental conditions

1.3.1 General

Except where other allowable environmental conditions are stated in the accompanying documents this standard applies to equipment installed, used or kept in locations where the following environmental conditions prevail:

  1. the ambient temperature falls within the range 10 °C to 40 °C;

  2. the relative humidity falls within the range 30 % to 75 %;

  3. the atmospheric pressure falls within the range 70 kPa to 110 kPa (700 mbar to 1 100 mbar).

1.3.2 Transport and storage

The allowable environmental conditions for transport and storage shall be stated in the accompanying documents.



Methods of test for obtaining data.