ASTM F1741-05
Historical Standard: ASTM F1741-05 Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
SUPERSEDED (see Active link, below)
ASTM F1741
1. Scope
1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits by the insertion of a machine-made field-fabricated spiral wound liner pipe into an existing pipeline. For existing pipelines 6 to 48 in., after insertion, the spiral wound liner pipe is expanded until it presses against the interior surface of the existing pipeline. Alternatively, for existing pipelines 6 to 108 in. in diameter, the spiral wound liner pipe is inserted as a fixed diameter into the existing pipeline and is not expanded, and the annular space between the spiral wound liner pipe and the existing pipe is grouted. This rehabilitation process can be used in a variety of gravity applications such as sanitary sewers, storm sewers, culverts, and process piping.
1.2 The values in parentheses are provided for information purposes only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.3.1 Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C39/C39M Test Method for Compressive Strength of Cylindrical Concrete Specimens
C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
C495 Test Method for Compressive Strength of Lightweight Insulating Concrete
D883 Terminology Relating to Plastics
D1600 Terminology for Abbreviated Terms Relating to Plastics
F412 Terminology Relating to Plastic Piping Systems
F1417 Practice for Installation Acceptance of Plastic Non-pressure Sewer Lines Using Low-Pressure Air
F1697 Specification for Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-Wound Liner Pipe Rehabilitation of Existing Sewers and Conduit
Uni-Bell Standard
UNI-B-5-89 Recommended Practice for the Installation of PVC Sewer Pipe Available from Uni-Bell, 2655 Villa Creek Drive, Suite 155, Dallas TX 75234.Keywords
expandable; gravity applications; installation-insertion; PVC profile strip; rehabilitation; spiral wound liner pipe
; Installation--plastic pipe materials/applications; Rehabilitation--sewerlines; Underground installation--water supply/distribution systems; Poly(vinyl chloride)(PVC) pipe; Poly(vinyl
chloride)(PVC) profile strip/liner; Sewer pipe (thermoplastic); Spiral wound PVC liner pipe; Conduits; Liner; Liner pipe; Machine spiral wound PVC liner pipe ;
ICS Code
ICS Number Code 23.040.20 (Plastic pipes); 83.080.20 (Thermoplastic materials)
DOI: 10.1520/F1741-05
ASTM International is a member of CrossRef.