Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
FORMAT
EDITION
to
PUBLISHER
(1)
(338)
(589)
(599)
(55)
(234)
(1006)
(690)
(2183)
(117)
(95207)
(63)
(575)
(124)
(33)
(21)
(20)
(95391)
(3)
(17)
(1)
(374)
(322)
(6938)
(241)
(21)
(6)
(1667)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    E2465-23 Standard Test Method for Analysis of Ni-Base Alloys by Wavelength Dispersive X-Ray Fluorescence Spectrometry
    Edition: 2023
    $113.57
    Unlimited Users per year

Description of ASTM-E2465 2023

ASTM E2465-23

Historical Standard: Standard Test Method for Analysis of Ni-Base Alloys by Wavelength Dispersive X-Ray Fluorescence Spectrometry




ASTM E2465

Scope

1.1 This test method covers the analysis of nickel and cobalt based alloys by wavelength dispersive X-ray fluorescence spectrometry for determination of the following elements:

Element

Composition Range

Aluminum

0.0X  to X.XX

Chromium

0.XX  to XX.XX

Copper

0.0X  to XX.XX

Cobalt

0.XX  to XX.XX

Hafnium

0.0X to 0.XX

Iron

0.XX  to XX.XX

Manganese

0.XX to X.XX

Molybdenum

0.0X  to XX.XX

Nickel

XX.XX  to XX.XX

Niobium

0.XX  to X.XX

Phosphorus

0.00X to 0.0XX

Silicon

0.0X to 0.XX

Tantalum

0.00X to X.XX

Titanium

0.XX to X.XX

Tungsten

0.XX to X.XX

Vanadium

0.00X to 0.XX

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This method has been interlaboratory tested for the elements and quantification ranges specified in 1.1. The ranges in 1.1 indicate intervals within which results have been demonstrated to be quantitative by the interlaboratory study. It may be possible to extend this method to other elements or different composition ranges provided that a method validation study as described in Guide E2857 is performed and that the results of this study show that the method extension is meeting laboratory data quality objectives.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


Keywords

cobalt alloys; Nickel alloys; spectrometric analysis; X-ray fluorescence;


ICS Code

ICS Number Code 77.040.20 (Non-destructive testing of metals)


DOI: 10.1520/E2465-23