Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
FORMAT
EDITION
to
PUBLISHER
(1)
(337)
(589)
(55)
(234)
(996)
(690)
(2161)
(117)
(94624)
(54)
(575)
(124)
(33)
(21)
(20)
(94991)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    E2033/E2033M-24 Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method) (Redline)
    Edition: 2024
    $113.57
    Unlimited Users per year

Description of ASTM-E2033/E2033M 2024

ASTM E2033/E2033M-24

Redline Standard: Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)




ASTM E2033/E2033M

Scope

1.1 This practice covers the minimum requirements for computed radiographic (CR) examination for metallic and nonmetallic materials using X-ray or gamma radiation.

1.2 Applicability—The requirements in this practice are intended to control the quality of computed radiographic examinations and are not intended to establish acceptance criteria for parts or materials.

1.3 Basis of Application—The requirements of this practice, Practice E2445, and E2446 shall be used together. The requirements of Practice E2445 will provide the baseline performance evaluation and long term stability test procedures for the CR system. Practice E2446 CR performance levels are recommended in Table 1. The user of the CR system shall establish a written procedure that addresses the specific requirements and tests to be used in their application and shall be approved by the Cognizant Radiographic Level 3 before examination of production hardware. The items that shall be determined and addressed in the written procedure are:

(a) Personnel qualification and certification.

(b) Minimum effective pixel coverage appropriate to the acceptance criteria and to meet the radiographic image quality level requirements of Table 1.

(c) Additional tests in accordance with Practice E2445 deemed appropriate.

(d) Organizations using a gamma source or radiation energy above 320 kV may need to modify the E2445 tests, gauges, or both.

(e) Maximum allowed unsharpness when other than Table 1.

(f) The method used to provide image traceability to the part and the examination facility.

1.3.1 This practice also requires the user to perform a system qualification suitable for its intended purpose and to issue a system qualification report (see subsection 7.1). Additionally, the user shall develop part specific inspection procedures (see subsections 5.5 and 7.5).

1.4 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Where applicable, SI units are shown in brackets [xx].

1.5 Compliance—Systems, equipment and materials that do not comply with this practice shall require a waiver from the Cognizant Engineering Organization (CEO).

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


Keywords

computed radiography; computed radiology; image; image quality indicator; imaging plate; IP; IQI; NDT; nondestructive testing; radiographic testing; scanner; X-ray;


ICS Code

ICS Number Code 87.060.10 (Pigments and extenders)


DOI: 10.1520/E2033_E2033M-24

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $923.88 Buy
VAR
ASTM
[+] $4,507.56 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

GROUPS