FORMAT
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E2018 1999ASTM E2018-99Historical Standard: Standard Guide for Property Condition Assessments: Baseline Property Condition Assessment ProcessASTM E2018Scope 1.1 Purpose—The purpose of this guide is to define good commercial and customary practice in the United States of America for conducting a baseline property condition assessment (PCA) of the improvements located on a parcel of commercial real estate by performing a walk-through survey and conducting research as outlined within this guide. 1.1.1 Physical Deficiencies—In defining good commercial and customary practice for conducting a baseline PCA, the goal is to identify and communicate physical deficiencies to a user. The term physical deficiencies means the presence of conspicuous defects or material deferred maintenance of a subject property's material systems, components, or equipment as observed during the field observer's walk-through survey. This definition specifically excludes deficiencies that may be remedied with routine maintenance, miscellaneous minor repairs, normal operating maintenance, etc., and excludes de minimis conditions that generally do not present material physical deficiencies of the subject property. 1.1.2 Walk-Through Survey—This guide outlines procedures for conducting a walk-through survey to identify the subject property's material physical deficiencies, and recommends various systems, components, and equipment that should be observed by the field observer and reported in the property condition report (PCR). 1.1.3 Document Reviews and Interviews—The scope of this guide includes document reviews, research, and interviews to augment the walk-through survey so as to assist the consultant's understanding of the subject property and identification of physical deficiencies. 1.1.4 Property Condition Report—The work product resulting from completing a PCA in accordance with this guide is a PCR. The PCR incorporates the information obtained during the Walk-Through Survey, the Document Review and Interviews sections of this guide, and includes opinions of probable costs for suggested remedies of the physical deficiencies identified. 1.2 Objectives—Objectives in the development of this guide are: (1) define good commercial and customary practice for the PCA of primary commercial real estate improvements; (2) facilitate consistent and pertinent content in PCRs; (3) develop practical and reasonable recommendations and expectations for site observations, document reviews and research associated with conducting PCAs and preparing PCRs; (4) establish reasonable expectations for PCRs; (5) assist in developing an industry baseline standard of care for appropriate observations and research; and (6) recommend protocols for consultants for communicating observations, opinions, and recommendations in a manner meaningful to the user. 1.3 Considerations Beyond Scope—The use of this guide is strictly limited to the scope set forth in this section. Section and of this guide identify, for informational purposes, certain physical conditions that may exist on the subject property, and certain activities or procedures (not an all inclusive list) that are beyond the scope of this guide but may warrant consideration by parties to a commercial real estate transaction. 1.4 Organization of This Guide—This guide consists of several sections, an Annex and two Appendixes. Section 1 is the Scope. Section 2 on Terminology contains definitions of terms both unique to this guide and not unique to this guide, and acronyms. Section 3 sets out the Significance and Use of this guide, and Section 4 describes the User's Responsibilities. Sections 5 through 10 provide guidelines for the main body of the PCA, including the scope of the Walk-Through Survey, preparation of the Opinions of Probable Costs to Remedy Physical Deficiencies, and preparation of the PCR. Section 11 provides additional information regarding out of scope considerations (see 1.3). Annex A1 provides requirements relating to specific asset types, and where applicable, such requirements are to be considered as if integral to this guide. Appendix X1 provides the user with additional PCA scope considerations, whereby a user may increase this guide's baseline scope of due diligence to be exercised by the consultant. Appendix X2 outlines the ADA Accessibility Survey. 1.5 Multiple Buildings—Should the subject property consist of multiple buildings, it is the intent of this guide that only a single PCR be produced by the consultant to report on all of the buildings on the subject property. 1.6 Safety Concerns—This guide does not purport to address all of the safety concerns, if any, associated with the walk-through survey. It is the responsibility of the consultant using this guide to establish appropriate safety and health practices when conducting a PCA. Keywords property condition assessment; PCA; real estate; baseline PCA; walk-through survey ICS Code ICS Number Code 13.040.20 (Ambient atmospheres) DOI: 10.1520/E2018-99 The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|