ASTM D6759-02
Historical Standard: ASTM D6759-02 Standard Practice for Sampling Liquids Using Grab and Discrete Depth Samplers
SUPERSEDED (see Active link, below)
ASTM D6759
1. Scope
1.1 This practice describes sampling devices and procedures for collecting samples of liquids or sludges, or both, whose upper surface can be accessed by the suitable device. These devices may be used to sample tanks that have an appropriately sized and located sampling port.
1.2 This practice describes and discusses the advantages and limitations of the following commonly used equipment, some of which can be used for both grab and discrete depth sampling: dipper, liquid grab sampler, swing jar sampler, Bacon Bomb, Kemmerer sampler, Discrete Level sampler, liquid profiler, lidded sludge/water sampler, peristaltic pump, and the Syringe sampler.
1.3 This practice provides instructions on the use of these samplers.
1.4 This practice does not address sampling devices for collecting ground water.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D4687 Guide for General Planning of Waste Sampling
D4840 Guide for Sample Chain-of-Custody Procedures
D5088 Practice for Decontamination of Field Equipment Used at Waste Sites
D5283 Practice for Generation of Environmental Data Related to Waste Management Activities: Quality Assurance and Quality Control Planning and Implementation
D5358 Practice for Sampling with a Dipper or Pond Sampler
D5612 Guide for Quality Planning and Field Implementation of a Water Quality Measurement Program
D5681 Terminology for Waste and Waste Management
D5743 Practice for Sampling Single or Multilayered Liquids, With or Without Solids, in Drums or Similar Containers
D5792 Practice for Generation of Environmental Data Related to Waste Management Activities: Development of Data Quality Objectives
D5956 Guide for Sampling Strategies for Heterogeneous Wastes
D6044 Guide for Representative Sampling for Management of Waste and Contaminated Media
D6051 Guide for Composite Sampling and Field Subsampling for Environmental Waste Management Activities
D6232 Guide for Selection of Sampling Equipment for Waste and Contaminated Media Data Collection Activities
D6233 Guide for Data Assessment for Environmental Waste Management Activities
D6311 Guide for Generation of Environmental Data Related to Waste Management Activities: Selection and Optimization of Sampling Design
D6323 Guide for Laboratory Subsampling of Media Related to Waste Management Activities
D6538 Guide for Sampling Wastewater With Automatic Samplers
D6699 Practice for Sampling Liquids Using Bailers
Keywords
discrete depth sampling; grab sampling; liquid; sampling; sampling equipment; waste management; Bacon bomb sampling; Dipper sampler; Discrete depth sampling; Environmental sampling/testing; Grab sampling; Kemmerer sampler; Lidded sludge/water sampler; Peristatic pumps; Swing jar sampler; Syringe sampler;
ICS Code
ICS Number Code 13.030.20 (Liquid wastes. Sludge)
DOI: 10.1520/D6759-02
ASTM International is a member of CrossRef.