Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Filters:
FORMAT
EDITION
to
PUBLISHER
(1)
(337)
(589)
(54)
(234)
(996)
(657)
(2161)
(117)
(94394)
(54)
(568)
(124)
(33)
(21)
(20)
(94534)
(3)
(17)
(1)
(374)
(315)
(6631)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    D6289-13 Standard Test Method for Measuring Shrinkage from Mold Dimensions of Molded Thermosetting Plastics
    Edition: 2013
    $91.10
    Unlimited Users per year

Description of ASTM-D6289 2013

ASTM D6289 - 13

Standard Test Method for Measuring Shrinkage from Mold Dimensions of Molded Thermosetting Plastics

Active Standard ASTM D6289 | Developed by Subcommittee: D20.09

Book of Standards Volume: 08.03




ASTM D6289

Significance and Use

4.1 Compression Molding In compression molding, the difference between the dimensions of a mold and of the molded article produced therein from a given material vary according to the design and operation of the mold. It is probable that shrinkage will approach a minimum where design and operation are such that a maximum of material is forced solidly into the mold cavity or some part of it, or where the molded article is hardened to a maximum while still under pressure, particularly by cooling. In contrast, shrinkages are higher where the charge must flow in the mold cavity but does not receive and transmit enough pressure to be forced firmly into all its recesses, or where the molded article is not fully hardened when discharged. The plasticity of the material used affects shrinkage insofar as it affects the retention and compression of the charge.

4.2 Injection Molding In injection molding, as in compression molding, the differences between the dimensions of the mold and of the molded article produced therein from a given material vary according to the design and operation of the mold. The differences vary with the type and size of molding machine, the thickness of molded sections, the degree and direction of flow or movement of material in the mold, the size of the nozzle, sprue, runner, and gate, the cycle on which the machine is operated, the temperature of the mold, and the length of time that follow-up pressure is maintained. As in the case of compression molding, shrinkages will approach a minimum where design and operation are such that a maximum of material is forced solidly into the mold cavity and where the molded article is hardened to a maximum while still under pressure as a result of the use of a runner, sprue, and nozzle of proper size, along with proper dwell. As in compression molding, shrinkages are higher where the charge must flow in the mold cavity but does not receive and transmit enough pressure to be forced firmly into all of the recesses of the mold. The plasticity of the material used affects shrinkage indirectly, in that the more readily plasticized material will require a lower molding temperature.

4.3 Transfer Molding In transfer molding, as in compression or injection molding, the difference between the dimensions of the mold and of the molded article produced therein from a given material vary according to the design and operation of the mold. It is affected by the size and temperature of the pot or cylinder and the pressure on it, as well as on mold temperature and molding cycle. Direction of flow is not as important a factor.

4.4 Materials Standards Always refer to material standards for special treatment prior to molding, molding conditions and special handling of the test specimens after molding. In the event the material standard is unavailable, contact the manufacturer for these recommendations.

4.5 Utility Measurement of batch-to-batch consistency in initial shrinkage from mold to molded dimensions is useful for evaluating the quality of thermosetting plastics.

1. Scope

1.1 This test method is intended to measure shrinkage from mold cavity to molded dimensions of thermosetting plastics when molded by compression, injection, or transfer under specified conditions.

1.2 This test method provides for the measurement of shrinkage of thermosetting plastics from their molds both initially (within 16 to 72 h of molding) and after aging (postshrinkage at elevated temperatures).

1.3 This method will give comparable data based on standard specimens and can not predict absolute values in actual molded parts with varying flow paths, wall thicknesses, pressure gradiants and process conditions. Differences in mold shrinkage generally is observed between the specimen geometries described in this test method.

1.4 Knowledge of the initial shrinkage of plastics is important for the construction of molds and knowledge of post molding shrinkage is important for determining the suitability of the molding material for manufacturing thermosetting plastic components with accurate dimensions.

1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 1 This test method and ISO 2577-1984 are equivalent when bars of 120 mm length, 15 mm width, and 10 mm thickness are used for compression molding; or flat, square plaques approximately 120 by 120 by 4 mm are used for injection molding.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

D618 Practice for Conditioning Plastics for Testing

D796 Practice for Compression Molding Test Specimens of Phenolic Molding Compounds

D883 Terminology Relating to Plastics

D1896 Practice for Transfer Molding Test Specimens of Thermosetting Compounds

D3419 Practice for In-Line Screw-Injection Molding Test Specimens From Thermosetting Compounds

D5224 Practice for Compression Molding Test Specimens of Thermosetting Molding Compounds

E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method


Keywords

molding shrinkage; post-molding shrinkage; thermoset plastics;


ICS Code

ICS Number Code 83.080.10 (Thermosetting materials)


DOI: 10.1520/D6289-13

ASTM International is a member of CrossRef.

ASTM D6289

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,278.52 Buy
VAR
ASTM
[+] $3,362.03 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

GROUPS