ASTM D4167-97(2002)
Historical Standard: ASTM D4167-97(2002) Standard Specification for Fiber-Reinforced Plastic Fans and Blowers
SUPERSEDED (see Active link, below)
ASTM D4167
1. Scope
1.1 This specification covers centrifugal and axial fans and blowers with airstream components fabricated of fiber-reinforced thermoset plastics (FRP) for corrosion resistance. Internal structures may include encapsulated metal fastening devices, hubs, and shafts.
1.2 Reinforcing materials other than fibrous glass may be used in the fabrication, provided the fans and blowers produced meet all the requirements of this specification.
1.3 The term 'fans' as used in this specification includes fans and blowers, both centrifugal and axial.
1.4 The purpose of this specification is to provide users, system designers, specifiers, and manufacturers of FRP fans with minimum standards for fan construction and a common basis for determining safe operating speeds.
1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.
Note 1There is no similar or equivalent ISO standard.
Note 2Appendix X2 contains a list of documents that may be of interest to designers of fan systems.
1.6 This standard does not puport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and helath practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C582 Specification for Contact-Molded Reinforced Thermosetting Plastic (RTP) Laminates for Corrosion-Resistant Equipment
D883 Terminology Relating to Plastics
D2563 Practice for Classifying Visual Defects in Glass-Reinforced Plastic Laminate Parts
Other Standards
ANSIS2.19 Balance Quality of Rotating Rigid Bodies Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.Keywords
axial blowers; centrifugal blowers; fan balancing; fan housing; fan wheel; fiber-reinforced plastic fans (frp); safe operating speed; Blowers; Fans; Fiber-reinforced-plastic (FRP); Plastics specifications; Reinforced thermosetting plastics (RTP) specifications;
ICS Code
ICS Number Code 23.120 (Ventilators. Fans. Air-conditioners)
DOI: 10.1520/D4167-97R02