ASTM D3167-97
Historical Standard: ASTM D3167-97 Standard Test Method for Floating Roller Peel Resistance of Adhesives
SUPERSEDED (see Active link, below)
ASTM D3167
1. Scope
1.1 This test method covers the determination of the relative peel resistance of adhesive bonds between one rigid adherend and one flexible adherend when tested under specified conditions of preparation and testing.
1.2 A variation in thickness of the adherends will generally influence the test values. For this reason, the thickness of the sheets used to make the test specimens shall be specified in the material specification. When no thickness is specified, the flexible adherend shall be 0.63 mm (0.025 in.) thick and the rigid adherend shall be 1.63 mm (0.064 in.) thick.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use .
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
B209 Specification for Aluminum and Aluminum-Alloy Sheet and Plate
D907 Terminology of Adhesives
D1781 Test Method for Climbing Drum Peel for Adhesives
E4 Practices for Force Verification of Testing Machines
Keywords
adhesives; assemblies; bonds; laminates; metal; peel; roller; Adhesive bonds; Assemblies; Bond strength--adhesives; Floating roller test; Laminates; Metallic adhesives; Metal-to-metal peel strength; Peel strength tests--adhesives; Roller;
ICS Code
ICS Number Code 83.180 (Adhesives)
DOI: 10.1520/D3167-97