ASTM A653/A653M-09
Historical Standard: ASTM A653/A653M-09 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
SUPERSEDED (see Active link, below)
ASTM A653 / A653M
1. Scope
1.1 This specification covers steel sheet, zinc-coated (galvanized) or zinc-iron alloy-coated (galvannealed) by the hot-dip process in coils and cut lengths.
1.2 The product is produced in various zinc or zinc-iron alloy-coating weights [masses] or coating designations as shown in Table 1and in Table S2.1.
1.3 Product furnished under this specification shall conform to the applicable requirements of the latest issue of Specification A 924/A 924M , unless otherwise provided herein.
1.4 The product is available in a number of designations, grades and classes in four general categories that are designed to be compatible with different application requirements.
1.4.1 Steels with mandatory chemical requirements and typical mechanical properties.
1.4.2 Steels with mandatory chemical requirements and mandatory mechanical properties.
1.4.3 Steels with mandatory chemical requirements and mandatory mechanical properties that are achieved through solid-solution or bake hardening.
1.5 This specification is applicable to orders in either inch-pound units (as A 653) or SI units (as A 653M). Values in inch-pound and SI units are not necessarily equivalent. Within the text, SI units are shown in brackets. Each system shall be used independently of the other.
1.6 Unless the order specifies the M designation (SI units), the product shall be furnished to inch-pound units.
1.7 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this specification.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
TABLE 1 Weight [Mass] of Coating Requirements A , B , C
Note Use the information provided in 8.1.3 to obtain the approximate coating thickness from the coating weight [mass].
Minimum Requirement D | ||||
---|---|---|---|---|
Triple-Spot Test |
Single-Spot Test | |||
Inch-Pound Units |
||||
Type | Coating Designation |
Total Both Sides, oz/ft 2 |
One Side, oz/ft 2 |
Total Both Sides, oz/ft 2 |
Zinc | G01 | no minimum | no minimum | no minimum |
G30 | 0.30 | 0.10 | 0.25 | |
G40 | 0.40 | 0.12 | 0.30 | |
G60 | 0.60 | 0.20 | 0.50 | |
G90 | 0.90 | 0.32 | 0.80 | |
G100 | 1.00 | 0.36 | 0.90 | |
G115 | 1.15 | 0.40 | 1.00 | |
G140 | 1.40 | 0.48 | 1.20 | |
G165 | 1.65 | 0.56 | 1.40 | |
G185 | 1.85 | 0.64 | 1.60 | |
G210 | 2.10 | 0.72 | 1.80 | |
G235 | 2.35 | 0.80 | 2.00 | |
G300 | 3.00 | 1.04 | 2.60 | |
G360 | 3.60 | 1.28 | 3.20 | |
Zinc-iron alloy | A01 | no minimum | no minimum | no minimum |
A25 | 0.25 | 0.08 | 0.20 | |
A40 | 0.40 | 0.12 | 0.30 | |
A60 | 0.60 | 0.20 | 0.50 | |
SI Units |
||||
Type |
Coating Designation |
Total Both Sides, g/m 2 |
One Side, g/m 2 |
Total Both Sides, g/m 2 |
Zinc | Z001 | no minimum | no minimum | no minimum |
Z90 | 90 | 30 | 75 | |
Z120 | 120 | 36 | 90 | |
Z180 | 180 | 60 | 150 | |
Z275 | 275 | 94 | 235 | |
Z305 | 305 | 110 | 275 | |
Z350 | 350 | 120 | 300 | |
Z450 | 450 | 154 | 385 | |
Z500 | 500 | 170 | 425 | |
Z550 | 550 | 190 | 475 | |
Z600 | 600 | 204 | 510 | |
Z700 | 700 | 238 | 595 | |
Z900 | 900 | 316 | 790 | |
Z1100 | 1100 | 390 | 975 | |
Zinc-iron alloy | ZF001 | no minimum | no minimum | no minimum |
ZF75 | 75 | 24 | 60 | |
ZF120 | 120 | 36 | 90 | |
ZF180 | 180 | 60 | 150 |
A The coating designation is the term by which the minimum triple spot, total both sides coating weight [mass] is specified. Because of the many variables and changing conditions that are characteristic of continuous hot-dip coating lines, the zinc or zinc-iron alloy coating is not always evenly divided between the two surfaces of a coated sheet; nor is it always evenly distributed from edge to edge. However, the minimum triple-spot average coating weight (mass) on any one side shall not be less than 40 % of the single-spot requirement.
B As it is an established fact that the atmospheric corrosion resistance of zinc or zinc-iron alloy-coated sheet products is a direct function of coating thickness (weight (mass)), the selection of thinner (lighter) coating designations will result in almost linearly reduced corrosion performance of the coating. For example, heavier galvanized coatings perform adequately in bold atmospheric exposure whereas the lighter coatings are often further coated with paint or a similar barrier coating for increased corrosion resistance. Because of this relationship, products carrying the statement meets ASTM A 653/A 653M requirements should also specify the particular coating designation.
C International Standard, ISO 3575, continuous hot-dip zinc-coated carbon steel sheet contains Z100 and Z200 designations and does not specify a ZF75 coating.
D No minimum means that there are no established minimum requirements for triple- and single-spot tests.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
A90/A90M Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings
A370 Test Methods and Definitions for Mechanical Testing of Steel Products
A568/A568M Specification for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for
A902 Terminology Relating to Metallic Coated Steel Products
A924/A924M Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
D7396 Guide for Preparation of New, Continuous Zinc-Coated (Galvanized) Steel Surfaces for Painting
E517 Test Method for Plastic Strain Ratio r for Sheet Metal
E646 Test Method for Tensile Strain-Hardening Exponents (n -Values) of Metallic Sheet Materials
ISO Standard
ISO 4998 Continuous Hot-Dip Zinc-Coated Carbon Steel of Structural QualityKeywords
alloyed coating; bake hardenable steel; high strength low alloy; minimized spangle coating; sheet steel; solution hardened steel; spangle; steel; steel sheet; structural steel; zinc; zinc coated (galvanized); zinc iron-alloy; zinc iron-alloy coated: Composition analysis--metals/alloys; Galvannealed steel sheet--specifications; Hot-dip (galvanized) coatings--specifications; Hot-dip processed coatings--specifications; HSLA (high-strength low-alloy) steel--specifications; Minimized spangle coating; Spangle; Zinc-coated steel sheet--specifications; Zinc electrodeposited coatings--specifications;
ICS Code
ICS Number Code 77.140.50 (Flat steel products and semi-products)
DOI: 10.1520/A0653_A0653M-09
ASTM International is a member of CrossRef.