Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
This publication is not part of the Official Compilation of Codes, Rules and Regulations of the State of New York.
Read more...
This software contains information which is proprietary to and copyrighted by or licensed to International Code Council, Inc. The portions of information copyrighted by or licensed to the International Code Council, Inc., have been obtained and reproduced with permission. The acronym ICC®, the ICC logo, 2007 Energy Conservation Construction Code of New York State are federally protected trademarks and service marks of ICC. All other code titles are the trademarks and services marks of the International Code Council, Inc. ALL RIGHTS RESERVED. Without advance written permission from the International Code Council, Inc., no part of the International Code Council, Inc.'s copyrighted or licensed material may be reproduced, distributed or transmitted in any form of by any means, including, without limitation, electronic, optical or mechanical means (by way of example and not limitation, photocopying, printing, or recording by or in an information storage retrieval system). For information on permission to copy the International Code Council, Inc. materials, please contact: Publications, 4051 West Flossmoor Road, Country Club Hills, IL 60478. Phone 1-888-ICC-SAFE (422-7233). Show less...
Energy Conservation Construction Code of New York State, 2007
- ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE 2007
- COPYRIGHT © 2007
- ACKNOWLEDGMENTS
- TABLE OF CONTENTS
- CHAPTER 1 ADMINISTRATION AND ENFORCEMENT [Go to Page]
- SECTION 101 SCOPE AND GENERAL REQUIREMENTS
- SECTION 102 MATERIALS, SYSTEMS AND EQUIPMENT [Go to Page]
- TABLE 102.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS
- TABLE 102.1.3(2) DEFAULT DOOR U-FACTORS
- TABLE 102.1.3(3) DEFAULT GLAZED FENESTRATION SHGC
- SECTION 103 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
- SECTION 104 CONSTRUCTION DOCUMENTS
- SECTION 105 ADMINISTRATION AND ENFORCEMENT
- SECTION 106 VALIDITY
- SECTION 107 REFERENCED STANDARDS
- CHAPTER 2 DEFINITIONS [Go to Page]
- SECTION 201 GENERAL
- SECTION 202 GENERAL DEFINITIONS
- CHAPTER 3 CLIMATE ZONES [Go to Page]
- SECTION 301 CLIMATE ZONES [Go to Page]
- TABLE 301.1 NEW YORK STATE RESIDENTIAL AND COMMERCIAL CLIMATE ZONES [Go to Page]
- TABLE 301.1—continued NEW YORK STATE RESIDENTIAL AND COMMERCIAL CLIMATE ZONES [Go to Page]
- TABLE 301.1—continued NEW YORK STATE RESIDENTIAL AND COMMERCIAL CLIMATE ZONES
- SECTION 302 DESIGN CONDITIONS
- CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY [Go to Page]
- SECTION 401 GENERAL
- SECTION 402 BUILDING THERMAL ENVELOPE [Go to Page]
- TABLE 402.1(1) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
- TABLE 402.1(2 )ALTERNATIVE INSULATION REQUIREMENTS BY COMPONENTa See Section 402.1, Exception 3
- TABLE 402.1.2 EQUIVALENT U-FACTORSa
- TABLE 402.1.4 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT FOR RESIDENCES USING ELECTRIC RESISTANCE HEATING
- TABLE 402.2.4 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
- SECTION 403 SYSTEMS [Go to Page]
- TABLE 403.7 OPTIONAL MECHANICAL EQUIPMENT EFFICIENCY REQUIREMENTS
- SECTION 404 SIMULATED PERFORMANCE ALTERNATIVE [Go to Page]
- TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [Go to Page]
- TABLE 404.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [Go to Page]
- TABLE 404.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
- TABLE 404.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
- CHAPTER 5 RESERVED
- CHAPTER 6 RESERVED
- CHAPTER 7 RESERVED
- CHAPTER 8 BUILDING DESIGN FOR COMMERCIAL BUILDINGS [Go to Page]
- SECTION 801 GENERAL
- SECTION 802 BUILDING ENVELOPE REQUIREMENTS [Go to Page]
- TABLE 802.2(1) BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 10b [Go to Page]
- TABLE 802.2(1)—continued BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 10b
- TABLE 802.2(2) BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 11b [Go to Page]
- TABLE 802.2(2)—continued BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 11b
- TABLE 802.2(3) BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 12b [Go to Page]
- TABLE 802.2(3)—continued BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 12b
- TABLE 802.2(4) BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 13a [Go to Page]
- TABLE 802.2(4)—continued BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 13a
- TABLE 802.2(5) BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 14a [Go to Page]
- TABLE 802.2(5)—continued BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 14a
- TABLE 802.2(6) BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 1 [Go to Page]
- TABLE 802.2(6)—continued BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 15
- TABLE 802.2(7) BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 16 [Go to Page]
- TABLE 802.2(7)—continued BUILDING ENVELOPE REQUIREMENTSa through e - CLIMATE ZONE 16
- (EQUATION 8-1)
- SECTION 803 BUILDING MECHANICAL SYSTEMS [Go to Page]
- TABLE 803.2.2 (1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 803.2.2(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 803.2.2(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS
- TABLE 803.2.2(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 803.2.2(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 803.2.6 MINIMUM EQUIPMENT EFFICIENCY ECONOMIZER EXCEPTION
- TABLE 803.3.2(1) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 803.3.2(2) WATER CHILLING PACKAGES, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 803.3.2(3) COPS AND IPLVS FOR NONSTANDARD CENTRIFUGAL CHILLERS < 150 TONS
- TABLE 803.3.2(4) COPs AND IPLVS FOR NONSTANDARD CENTRIFUGAL CHILLERS 150 TONS, 300 TONS
- TABLE 803.3.2(5) COPS AND IPLVS FOR NONSTANDARD CENTRIFUGAL CHILLERS 300 TONS
- TABLE 803.3.2(6) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT
- (EQUATION 8-2)
- TABLE 803.3.7MINIMUM PIPE INSULATIONa(thickness in inches)
- SECTION 804 SERVICE WATER HEATING [Go to Page]
- TABLE 804.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
- SECTION 805
ELECTRICAL POWER AND LIGHTING SYSTEMS
- SECTION 806
TOTAL BUILDING PERFORMANCE [Go to Page]
- TABLE 805.5.2 INTERIOR LIGHTING POWER
- TABLE 805.6.1 NEMA CLASS 1 EFFICIENCY LEVELS FOR LIQUID-FILLED DISTRIBUTION TRANSFORMERS
- TABLE 805.6.2 NEMA CLASS 1 EFFICIENCY LEVELS FOR DRY-TYPE DISTRIBUTION TRANSFORMERS
- CHAPTER 9 RESERVED
- CHAPTER 10 REFERENCED STANDARDS [Go to Page]
- AAMA
- AMCA
- ANSI
- ARI
- ASHRAE
- ASME
- ASTM
- CTI
- DOE
- HI
- ICC
- IESNA
- NFRC
- SMACNA
- UL
- WDMA
- INDEX [Go to Page]