Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
ICC 400-2022: Standard on the Design and Construction of Log Structures, 2022
- ICC 400-2022 STANDARD ON THE DESIGN AND CONSTRUCTION OF LOG STRUCTURES
- COPYRIGHT
- FOREWORD
- TABLE OF CONTENTS
- CHAPTER 1: ADMINISTRATIVE PROVISIONS [Go to Page]
- SECTION 101 ADMINISTRATIVE PROVISIONS
- SECTION 102 APPLICABILITY
- SECTION 103 PROVISIONS FOR COMPLIANCE
- SECTION 104 COMPLIANCE ALTERNATIVES
- SECTION 105 CONVENTIONS
- SECTION 106 INSPECTIONS
- SECTION 107 FOUNDATIONS
- SECTION 108 DESIGN LOADS
- SECTION 109 REFERENCED DOCUMENTS
- CHAPTER 2: DEFINITIONS [Go to Page]
- SECTION 201 GENERAL
- SECTION 202 DEFINED TERMS
- SECTION 203 SYMBOLS
- CHAPTER 3: GENERAL REQUIREMENTS [Go to Page]
- SECTION 301 GENERAL
- SECTION 302 MATERIALS [Go to Page]
- TABLE 302.2.2.1.1 MOISTURE CONTENT OF SELECTED WOOD SPECIES AT FIBER SATURATION
- TABLE 302.2.1.2 LIST OF SPECIES COMBINATIONS [Go to Page]
- TABLE 302.2.1.2—continued LIST OF SPECIES COMBINATIONS
- TABLE 302.2.1.2—continued LIST OF SPECIES COMBINATIONS
- TABLE 302.2.1.2—continued LIST OF SPECIES COMBINATIONS
- TABLE 302.2.1.2—continued LIST OF SPECIES COMBINATIONS
- TABLE 302.2.1.2—continued LIST OF SPECIES COMBINATIONS
- TABLE 302.2.1.2—continued LIST OF SPECIES COMBINATIONS
- FIGURE 302.2.2.2.1 CLIMATE ZONE MAP
- TABLE 302.2.3.2(1) BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS [Go to Page]
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(1)—continued BASE DESIGN VALUES FOR SAWN ROUND AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.2(2) BASE DESIGN VALUES FOR WALL-LOGS [Go to Page]
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(2)—continued BASE DESIGN VALUES FOR WALL-LOGS
- TABLE 302.2.3.2(3) APPLICABILITY OF ADJUSTMENT FACTORS FOR WALL-LOGS AND SRTBs
- TABLE 302.2.3.4 SECTION PROPERTIES OF SAWN AND UNSAWN ROUND TIMBER BEAMS
- TABLE 302.2.3.5.1 ADJUSTMENT FACTORS FOR WALL-LOGS
- TABLE 302.2.3.10 WEIGHT OF LOG WALLS [Go to Page]
- TABLE 302.2.3.10—continued WEIGHT OF LOG WALLS
- FIGURE 302.2.4(1) NOTCHES AND BORED HOLES IN SINGLE-SPAN BEAMS
- FIGURE 302.2.4(2) NOTCHES AND HOLES IN MULTIPLE-SPAN BEAMS
- SECTION 303 FIRE-RESISTANCE RATINGS OF LOGS AND LOG ASSEMBLIES
- SECTION 304 PROVISIONS FOR SETTLING IN LOG STRUCTURES [Go to Page]
- TABLE 304.2.2.1.3 SHRINKAGE COEFFICIENTS
- TABLE 304.2.2.2.2.2 PRESCRIBED SETTLING ALLOWANCE FOR NONHORIZONTAL BEARING SURFACES
- TABLE 304.2.2.2.2.1 BEARING CAPACITY (lb/in) OF WALL-LOGS [Go to Page]
- TABLE 304.2.2.2.2.1—continued BEARING CAPACITY (lb/in) OF WALL-LOGS
- TABLE 304.2.2.3.3 PRESCRIBED SETTLING ALLOWANCE DUE TO SHRINKAGE
- SECTION 305 THERMAL ENVELOPE [Go to Page]
- TABLE 305.3.1.1 U-FACTOR OF LOG WALL (UW) BY LOG THICKNESS (WL) AND SPECIFIC GRAVITY (Gu) [Go to Page]
- TABLE 305.3.1.1—continued U-FACTOR OF LOG WALL (UW) BY LOG THICKNESS (WL) AND SPECIFIC GRAVITY (Gu)
- TABLE 305.3.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
- TABLE 305.4.3.2 HEAT CAPACITY OF SOLID WOOD
- SECTION 306 INFILTRATION
- CHAPTER 4: STRUCTURAL PROVISIONS [Go to Page]
- SECTION 401 GENERAL
- SECTION 402 PRESCRIPTIVE PROVISIONS
- SECTION 403 ENGINEERED PROVISIONS [Go to Page]
- TABLE 403.1 MAXIMUM DIAPHRAGM ASPECT RATIOS (HORIZONTAL OR SLOPED DIAPHRAGMS)
- SECTION 404 CONNECTIONS
- SECTION 405 FLOOR SYSTEMS
- SECTION 406 LOG WALLS
- SECTION 407 ROOF SYSTEMS
- CHAPTER 5: REFERENCED STANDARDS [Go to Page]
- ASTM
- AWC
- ICC
- UL
- APPENDIX A US CLIMATE ZONES BY COUNTY [Go to Page]
- TABLE A101.1 (IECC R301.1) CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa [Go to Page]
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa
- TABLE A101.1 (IECC R301.1)—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORYa [Go to Page]