Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
AWWA Manual M22 Sizing Water Service Lines and Meters, Fourth Edition, 2024
- Chapter 1
- Introduction
- OVERVIEW
- M22 TARGET AUDIENCE
- UPDATES
- CONSIDERATIONS WHEN SIZING WATER METERS AND SERVICE LINES
- REFERENCES
- Chapter 2
- Consumer Water Demands, Trends, and Considerations
- INTRODUCTION
- WATER-USE TRENDS
- WATER USE PATTERNS
- REFERENCES
- Chapter 3
- Demand Profiling for Optimal Meter Sizing
- ACCURATELY MEASURING CUSTOMER USAGE
- RECORDER DESIGN
- RECORDING DATA
- USING CUSTOMER USAGE DATA
- REFERENCES
- Chapter 4
- Estimating Peak Water Demands for Service Lines and Meters
- INTRODUCTION
- ESTIMATING PEAK DEMAND FOR NONRESIDENTIAL BUILDINGS
- Chapter 5
- Service-Line Sizing
- INTRODUCTION
- DATA REQUIRED
- HEAD LOSS
- PERFORMING SIZING CALCULATIONS
- REFERENCES
- Chapter 6
- Meter Sizing
- INTRODUCTION
- REVENUE IMPLICATIONS
- SYSTEM COMPONENTS POLICY REVIEW
- WATER METER SELECTION
- METER ARRANGEMENTS FOR FIRE SERVICES
- SUMMARY
- REFERENCES
- Appendix A
- Software to Size a Meter
- INTRODUCTION
- SUMMARY OF SOFTWARE OPERATION
- SETUP
- SIZING A METER
- Appendix B
- Flow Friction Loss Tables
- REFERENCES
- Figure 3-8 Flow data from an apartment building served by oversized 8-in. turbo meter
- Figure 3-7 Data presentation options
- Figure 3-6 Verification of data accuracy
- Figure 3-5 Recording demand profiles from large compound meters may require an adapter.
- Figure 3-4 Compound adapter and sensor
- Figure 3-3 Depiction of 4-min and 1-min data storage intervals
- Figure 3-2 �Flow recorder (right) collecting and storing a demand profile from a 3-in. water meter (left)
- Figure 5-2 Head loss from water main to customer
- Figure 5-1 Head loss versus flow rate curves
- Figure 5-3 Steps for determining pipe, meter, and other fitting sizes [Go to Page]
- Figure 5-4 Compound-meter pressure drop versus flow curves
- Figure 5-5 RPBP assembly pressure drop versus flow curves
- Figure A-4 Graphical analysis screen (sample from MeterSizer®)
- Figure A-3 Initial results screen (sample from MeterSizer®)
- Figure A-2 Customer information screen (sample from MeterSizer®)
- Table 2-1 National fixture standards and specifications
- Table 2-2 Per-capita residential indoor use
- Table 2-3 �Average per-account consumption and monthly peaking factors* for selected customer types in Oakland, Calif., area and Westminster, Colo.†
- Table 3-1 Meter maximum flowrate range example
- Table 5-1 Actual internal diameter versus nominal diameter
- Table 5-2 Minor loss k-values
- Table 5-3 Minor loss through meters
- Table 5-4 Minor loss through backflow prevention assemblies
- Table 5-5 Service-line sizing calculation spreadsheet (L = 200 ft, Q = 75 gpm)
- Table 6-1 Minor loss through meters
- Table 6-2 Typical uses for each type of meter classification
- Table B-1 Copper water tube properties—C=130—¾ in. nominal diameter
- Table B-2 Copper water tube properties—C=130—1 in. nominal diameter
- Table B-3 Copper water tube properties—C=130—1¼ in. nominal diameter
- Table B-4 Copper water tube properties—C=130—1½ in. nominal diameter
- Table B-5 Copper water tube properties—C=130—2 in. nominal diameter
- Table B-6 Copper water tube properties—C=130—2½ in. nominal diameter
- Table B-7 Copper water tube properties—C=130—3 in. nominal diameter
- Table B-8 Copper water tube properties—C=130—3½ in. nominal diameter
- Table B-9 copper water tube properties—C=130—4 in. nominal diameter
- Table B-10 Copper water tube properties—C=130—5 in. nominal diameter
- Table B-11 Copper water tube properties—C=130—6 in. nominal diameter
- Table B-12 Copper water tube properties—C=130—8 in. nominal diameter
- Table B-13 Polyvinyl chloride (PVC) pipe—C=130—¾ in. nominal diameter
- Table B-14 Polyvinyl chloride (PVC) pipe—C=130—1 in. nominal diameter
- Table B-15 Polyvinyl chloride (PVC) pipe—C=130—1¼ in. nominal diameter
- Table B-16 Polyvinyl chloride (PVC) pipe—C=130—1½ in. nominal diameter
- Table B-17 Polyvinyl chloride (PVC) pipe—C=130—2 in. nominal diameter
- Table B-18 Polyvinyl chloride (PVC) pipe—C=130—2½ in. nominal diameter
- Table B-19 Polyvinyl chloride (PVC) pipe—C=130—3 in. nominal diameter
- Table B-20 Polyvinyl chloride (PVC) pipe—C=130—3½ in. nominal diameter
- Table B-21 Polyvinyl chloride (PVC) pipe—C=130—4 in. nominal diameter
- Table B-22 Polyvinyl chloride (PVC) pipe—C=130—5 in. Nominal Diameter
- Table B-23 Polyvinyl chloride (PVC) pipe—C=130—6 in. nominal diameter
- Table B-24 Polyvinyl chloride (PVC) pipe—C=130—8 in. nominal diameter
- Table B-25 Polyethylene pipe—C=130—¾ in. nominal diameter
- Table B-26 Polyethylene pipe—C=130—1 in. nominal diameter
- Table B-27 Polyethylene pipe—C=130—1¼ in. nominal diameter
- Table B-28 Polyethylene pipe—C=130—1½ in. nominal diameter
- Table B-29 Polyethylene pipe—C=130—2 in. nominal diameter
- Table B-30 Polyethylene pipe—C=130—3 in. nominal diameter
- Table B-31 Cross-linked polyethylene (PEX) pipe—C=130—½ in. nominal diameter, 0.625
- Table B-32 Cross-linked polyethylene (PEX) pipe—C=130—⅝ in. nominal diameter, 0.75
- Table B-33 Cross-linked polyethylene (PEX) pipe—C=130—¾ in. nominal diameter, 0.875
- Table B-34 Cross-linked polyethylene (PEX) pipe—C=130—1 in. nominal diameter, 1.125
- Table B-35 Cross-linked polyethylene (PEX) pipe—C=130—1¼ in. nominal diameter, 1.375
- Table B-36 Cross-linked polyethylene (PEX) pipe—C=130—1½ in. nominal diameter, 1.625
- Table B-37 Cross-linked polyethylene (PEX) pipe—C=130—2 in. nominal diameter, 2.125
- Table B-38 Cross-linked polyethylene (PEX) pipe—C=130—2½ in. nominal diameter, 2.625
- Table B-39 Cross-linked polyethylene (PEX) pipe—C=130—3 in. nominal diameter, 3.125 [Go to Page]