Vermont Commercial Building Energy Standards, 2011
- 2011 VERMONT COMMERCIAL BUILDING ENERGY STANDARDS
- COPYRIGHT
- PREFACE
- EFFECTIVE USE OF THE 2011 COMMERCIAL BUILDING ENERGY STANDARDS
- TABLE OF CONTENTS
- CHAPTER 1: ADMINISTRATION [Go to Page]
- PART 1—SCOPE AND APPLICATION [Go to Page]
- SECTION 101 SCOPE AND GENERAL REQUIREMENTS
- SECTION 102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGNOR INSULATING SYSTEMS
- PART 2—ADMINISTRATION AND ENFORCEMENT [Go to Page]
- SECTION 103 CONSTRUCTION DOCUMENTS
- SECTION 104 INSPECTIONS
- SECTION 105 VALIDITY
- SECTION 106 REFERENCED STANDARDS
- CHAPTER 2: DEFINITIONS [Go to Page]
- SECTION 201 GENERAL
- SECTION 202 GENERAL DEFINITIONS
- CHAPTER 3: GENERAL REQUIREMENTS [Go to Page]
- SECTION 301 DESIGN CONDITIONS
- SECTION 302 MATERIALS, SYSTEMS AND EQUIPMENT [Go to Page]
- TABLE 302.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
- TABLE 302.1.3(2) DEFAULT DOOR U-FACTORS
- TABLE 302.1.3(3) DEFAULT GLAZED FENESTRATION SHGC
- CHAPTER 4: RESIDENTIAL ENERGY EFFICIENCY
- CHAPTER 5: COMMERCIAL ENERGY EFFICIENCY [Go to Page]
- SECTION 501 GENERAL
- SECTION 502 BUILDING ENVELOPE REQUIREMENTS [Go to Page]
- EQUATION 5-1
- TABLE 502.1(1) BUILDING ENVELOPE REQUIREMENTS–OPAQUE ASSEMBLIES AND ELEMENTSa,b
- TABLE 502.1(2) BUILDING ENVELOPE REQUIREMENTS–METAL BUILDING ASSEMBLY DESCRIPTIONS [Go to Page]
- TABLE 502.1(2)–continued BUILDING ENVELOPE REQUIREMENTS–METAL BUILDING ASSEMBLY DESCRIPTIONS
- TABLE 502.1(3) ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS
- TABLE 502.1(4) ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS
- TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION
- TABLE 502.4.3 MAXIMUM AIR INFILTRATION RATE FOR FENESTRATION ASSEMBLIES
- SECTION 503 BUILDING MECHANICAL SYSTEMS [Go to Page]
- TABLE 503.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS [Go to Page]
- TABLE 503.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
- TABLE 503.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS [Go to Page]
- TABLE 503.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
- TABLE 503.2.3(3) PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS [Go to Page]
- TABLE 503.2.3(3)—continued PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
- TABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS,WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 503.2.3(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 503.2.3(6) WATER CHILLING PACKAGES, EFFICIENCY REQUIREMENTSa
- EQUATION 5-2
- TABLE 503.2.8 MINIMUM PIPE INSULATIONa (thickness in inches)
- TABLE 503.2.11.1(1) FAN POWER LIMITATION
- TABLE 503.2.11.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
- TABLE 503.3.1.1.3(1) HIGH-LIMIT SHUTOFF CONTROL OPTIONS FOR AIR ECONOMIZERS
- TABLE 503.3.1.1.3(2) HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS
- TABLE 503.4.7 MAXIMUM HOT GAS BYPASS CAPACITY
- SECTION 504 SERVICE WATER HEATING (Mandatory) [Go to Page]
- TABLE 504.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
- SECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS (Mandatory) [Go to Page]
- TABLE 505.5.2(1) INTERIOR LIGHTING POWER ALLOWANCES BUILDING AREA METHOD
- TABLE 505.5.2(2) INTERIOR LIGHTING POWER ALLOWANCES—SPACE-BY-SPACE METHOD [Go to Page]
- Table 505.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES—SPACE-BY-SPACE METHOD [Go to Page]
- Table 505.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES—SPACE-BY-SPACE METHOD
- TABLE 505.6.2(1) EXTERIOR LIGHTING ZONES
- TABLE 505.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
- TABLE 505.8(1) MINIMUM NOMINAL EFFICIENCY FOR GENERAL PURPOSE DESIGN A AND DESIGN B MOTORS RATED 600 VOLTS OR LESSa
- TABLE 505.11(1) NEMA PREMIUM EFFICIENCY LEVELS FOR DRY-TYPE DISTRIBUTION TRANSFORMERS
- TABLE 505.11(2) NEMA CLASS 1 EFFICIENCY LEVELS FOR LIQUID-FILLED DISTRIBUTION TRANSFORMERS
- CHAPTER 6 REFERENCED STANDARDS [Go to Page]
- AAMA
- AHAM
- AHRI
- AMCA
- ANSI
- ASHRAE
- ASME
- ASTM
- CSA
- DASMA
- DOE
- ICC
- IESNA
- NFRC
- SMACNA
- UL
- WDMA
- INDEX
- HELPFUL LINKS [Go to Page]
- ICC WEBSITE
- ICC PRODUCT STORE
- IMMEDIATE DOWNLOADS 24/7 AT THE ECODES STORE
- ICC EVALUATION SERVICE - EVALUATION REPORTS OF PRODUCTS [Go to Page]