Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
International Energy Conservation Code, 2009
- IECC® INTERNATIONAL ENERGY CONSERVATION CODE® 2009
- IECC® INTERNATIONAL ENERGY CONSERVATION CODE® 2009 TITLE PAGE
- COPYRIGHT
- PREFACE
- EFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE
- ORDINANCE
- TABLE OF CONTENTS
- CHAPTER 1 ADMINISTRATION [Go to Page]
- PART 1—SCOPE AND APPLICATION [Go to Page]
- SECTION 101 SCOPE AND GENERAL REQUIREMENTS
- SECTION 102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
- PART 2—ADMINISTRATION AND ENFORCEMENT [Go to Page]
- SECTION 103 CONSTRUCTION DOCUMENTS
- SECTION 104 INSPECTIONS
- SECTION 105 VALIDITY
- SECTION 106 REFERENCED STANDARDS
- SECTION 107 FEES
- SECTION 108 STOP WORK ORDER
- SECTION 109 BOARD OF APPEALS
- CHAPTER 2 DEFINITIONS [Go to Page]
- SECTION 201 GENERAL
- SECTION 202 GENERAL DEFINITIONS
- CHAPTER 3 CLIMATE ZONES [Go to Page]
- SECTION 301 CLIMATE ZONES [Go to Page]
- FIGURE 301.1 CLIMATE ZONES
- TABLE 301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY [Go to Page]
- TABLE 301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
- TABLE 301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
- TABLE 301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
- SECTION 302 DESIGN CONDITIONS
- SECTION 303 MATERIALS, SYSTEMS AND EQUIPMENT [Go to Page]
- TABLE 303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
- TABLE 303.1.3(2) DEFAULT DOOR U-FACTORS
- TABLE 303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC
- CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY [Go to Page]
- SECTION 401 GENERAL
- SECTION 402 BUILDING THERMAL ENVELOPE [Go to Page]
- TABLE 402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT a
- TABLE 402.1.3 EQUIVALENT U-FACTORS a
- TABLE 402.2.5 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
- TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
- SECTION 403 SYSTEMS
- SECTION 404 ELECTRICAL POWER AND LIGHTING SYSTEMS
- SECTION 405 SIMULATED PERFORMANCE ALTERNATIVE (Performance) [Go to Page]
- TABLE 405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [Go to Page]
- TABLE 405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
- TABLE 405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNS a
- CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY [Go to Page]
- SECTION 501 GENERAL
- SECTION 502 BUILDING ENVELOPE REQUIREMENTS [Go to Page]
- TABLE 502.1.2 BUILDING ENVELOPE REQUIREMENTS OPAQUE ELEMENT, MAXIMUM U-FACTORS
- TABLE 502.2(1) BUILDING ENVELOPE REQUIREMENTS - OPAQUE ASSEMBLIES
- TABLE 502.2(2) BUILDING ENVELOPE REQUIREMENTS–OPAQUE ASSEMBLIES
- EQUATION 5-1
- TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION
- TABLE 502.4.4 MAXIMUM HOT GAS BYPASS CAPACITY
- SECTION 503 BUILDING MECHANICAL SYSTEMS [Go to Page]
- TABLE 503.2.3(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 503.2.3(2) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS [Go to Page]
- TABLE 503.2.3(2)—continued UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 503.2.3(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS
- TABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS,WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 503.2.3(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 503.2.3(6) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 503.2.3(7) WATER CHILLING PACKAGES, EFFICIENCY REQUIREMENTSa
- EQUATION 5-2
- TABLE 503.2.8 MINIMUM PIPE INSULATION (thickness in inches)
- TABLE 503.2.10.1(1) FAN POWER LIMITATION
- TABLE 503.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
- TABLE 503.3.1(1) ECONOMIZER REQUIREMENTS
- TABLE 503.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
- SECTION 504 SERVICE WATER HEATING( Mandatory) [Go to Page]
- TABLE 504.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
- SECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS (Mandatory) [Go to Page]
- TABLE 505.5.2 INTERIOR LIGHTING POWER ALLOWANCES [Go to Page]
- TABLE 505.5.2—continued INTERIOR LIGHTING POWER ALLOWANCES
- TABLE 505.6.2(1) EXTERIOR LIGHTING ZONES
- TABLE 505.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
- SECTION 506 TOTAL BUILDING PERFORMANCE [Go to Page]
- TABLE 506.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [Go to Page]
- TABLE 506.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
- TABLE 506.5.1(2) HVAC SYSTEMS MAP
- TABLE 506.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
- TABLE 506.5.1(4) NUMBER OF CHILLERS
- TABLE 506.5.1(5) WATER CHILLER TYPES
- CHAPTER 6 REFERENCED STANDARDS [Go to Page]
- AAMA
- AHRI
- AMCA
- ANSI
- ASHRAE
- ASME
- ASTM
- CSA
- DOE
- ICC
- IESNA
- NFRC
- SMACNA
- UL
- US—FTC
- WDMA
- INDEX
- EDITORIAL CHANGES
- GET YOUR CODES ELECTRONICALLY-ANYTIME, ANYWHERE
- ICC MEMBERSHIP INFORMATION
- INTRODUCING THE SAVE™ PROGRAM
- ICC TRAINING INFORMATION [Go to Page]