Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(20)
(19)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1621)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • ASTM
    E975-13 Standard Practice for X-Ray Determination of Retained Austenite in Steel with Near Random Crystallographic Orientation
    Edition: 2013
    $93.60
    Unlimited Users per year

Description of ASTM-E975 2013

ASTM E975-13

Historical Standard: Standard Practice for X-Ray Determination of Retained Austenite in Steel with Near Random Crystallographic Orientation (Withdrawn 2022)




ASTM E975

Scope

1.1 This practice covers the determination of retained austenite phase in steel using integrated intensities (area under peak above background) of X-ray diffraction peaks using chromium Kα or molybdenum Kα X-radiation.

1.2 The method applies to carbon and alloy steels with near random crystallographic orientations of both ferrite and austenite phases.

1.3 This practice is valid for retained austenite contents from 1 % by volume and above.

1.4 If possible, X-ray diffraction peak interference from other crystalline phases such as carbides should be eliminated from the ferrite and austenite peak intensities.

1.5 Substantial alloy contents in steel cause some change in peak intensities which have not been considered in this method. Application of this method to steels with total alloy contents exceeding 15 weight % should be done with care. If necessary, the users can calculate the theoretical correction factors to account for changes in volume of the unit cells for austenite and ferrite resulting from variations in chemical composition.

1.6 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

TABLE 1 Calculated Theoretical Intensities Using Chromium Kα RadiationA

hkl

Sinθ/λ

θ

f

Δf′

Δf"

/F/2

LP

P

TB

N2

R

(α iron, body-centered cubic, unit-cell dimension ao  = 2.8664Å):

110

0.24669

34.41

18.474

−1.6

0.9

1142.2

4.290

12

0.9577

0.001803B

101.5C

200

0.34887

53.06

15.218

−1.6

0.9

 745.0

2.805

 6

0.9172

0.001803B

 20.73C

211

0.42728

78.20

13.133

−1.6

0.8

 534.6

9.388

24

0.8784

0.001803B

190.8C

(γ iron, face-centered cubic, unit-cell dimension a o  = 3.60Å):

111

0.24056

33.44

18.687

−1.6

0.9

4684.4

4.554

 8

0.9597

0.0004594B

 75.24C

200

0.27778

39.52

17.422

−1.6

0.9

4018.3

3.317

 6

0.9467

0.0004594B

 34.78C

220

0.39284

64.15

14.004

−1.6

0.8

2472.0

3.920

12

0.8962

0.0004594B

 47.88C

A  Data from “International Tables for X-Ray Crystallography,” Physical and Chemical Tables , Vol III, Kynoch Press, Birmingham, England, 1962, pp. 60, 61, 210, 213; Weighted Kα1 and Kα2 value used (λ = 2.29092Å).
B  Temperature factor (T = e−2M) where M = B(sin 2 θ)/λ2 and 2B = 0.71. Also N is the reciprocal of the unit-cell volume.
C  Calculated intensity includes the variables listed that change with X-ray diffraction peak position.

Keywords

austenite; crystallographic orientation; ferrite; martensite; retained austenite; X-ray diffraction


ICS Code

ICS Number Code 77.080.20 (Steels)


DOI: 10.1520/E0975-13

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $4,507.56 Buy
VAR
ASTM
[+] $1,251.32 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X